Modifying existing screens
Before you make any changes to screens, refer to Planning screen and field changes
In Configuration Mode, you can make the following changes to screens:
-
Change the names of screens.
-
Change the screen layout from two columns to four columns.
-
Move fields to a different position on screens.
-
Add new fields to screens.
-
Delete fields so that they no longer appear on the screen, and / or reinstate deleted fields.
-
Remove fields from the database.
To modify any screen, you need to:
-
Access the screen in Configuration Mode.
-
Make the changes, using the following sections as a guide.
-
Select Save & Exit at the bottom of the screen. Alternatively, you can select Cancel & Exit at any time to cancel any changes you have made and keep the existing screen content and format.
Change the name (title) of a screen
-
Access the screen in Configuration Mode.
-
At the top of the screen, select Select here to edit the screen title.
-
Type the new name for the screen.
-
Select OK.
The screen name changes throughout the system, including Query Builder, but the name of the corresponding table in the database remains the same.
If you change the screen name, it is advisable to make a note of its original name in case you need to raise queries about the screen with the IRIS Cascade service desk.
Change the column layout of a screen
Screens in IRIS Cascade can have two columns (for example, Absence) or four columns (for example, Job & Salary).
To change the layout of a screen from two columns to four columns, select 2 Col/4 Col at the bottom of the screen, and then drag and drop the fields as required.
You must take care when using this option because you cannot revert to the original two-column design by selecting Cancel & Exit to go back to a two-column layout, you must move all the affected fields back into place manually. It is advisable to take a screenshot of the original screen layout before you change column settings.
Move a field to a different position
To move a field, drag and drop it to the position on the screen where you want it to be:
-
When you select the field to drag it, make sure your cursor is in the area to the right of the field name
-
When you drop the field, make sure your cursor is in the area to the right of the name of the field you are dropping on top of, not over the name of a field
Add a new field to a screen
Before you add a new field, make sure it is unhidden. Refer to Unhide a hidden field in Modifying fields.
-
Access the screen in Configuration Mode.
-
At the top of the screen, select Tables & Fields. The Configuration Menu screen appears.
-
Select Modify Existing Screen/Add and Remove Fields. The Configuration Menu > Modify Existing Screen/ Table screen appears.
-
In the Screen field, make sure the correct screen is selected.
-
In the Fields section:
-
Double-select dbl select to add new field.
-
Type a name for the field, as you want it to appear on screen. If you want the field name on screen to contain more than 15 characters, type a shorter name at this point to create the field name in the database. You can rename the field in Design Mode later.
-
In the Type field, select the appropriate field type from the drop-down menu, using the table below as a guide.
-
In the right-hand column, select Save.
-
|
Field type |
Description |
|
Text (up to 50 chars) |
Field for typing small amounts of text |
|
Yes/No |
Tick box |
|
Decimal (e.g. 10.5) |
Number field for adding decimal values |
|
Number (Whole number e.g. 10) |
Number field for adding whole numbers |
|
Form Separator |
Tool for separating sections of a screen, to make the sections clearer for self-service users |
|
Date |
Field for selecting a date from a calendar |
|
Text (narrative > 50 Chars) |
Notes field for typing large amounts of text |
|
Hierarchy Picker Field |
Field for selecting a hierarchy location |
|
Currency Field (e.g. £10.50) |
Field for adding monetary values |
|
Document Control |
Field for attaching documents to records |
|
Employee Picker |
Field for selecting an employee |
-
Repeat step 5 until you have added all fields needed.
-
Beside each field, select Add to Screen. Alternatively, tick Automatically add any new fields to the screen at the bottom of the screen.
-
At the bottom of the screen, select Save Changes.
-
On the Configuration Menu screen, select Close to return to the screen in Design Mode.
Remove a field from a screen
To remove a field from a screen (but not from the corresponding database table), select the field, and select Delete Control at the bottom of the screen.
This deletion method makes it easy to rectify mistakes. The field is removed from the screen, but remains in the corresponding database table, so you can reinstate it later if required. Data in the field is not lost.
Reinstate a deleted field
-
Access the screen in Configuration Mode.
-
At the top of the screen, select Tables & Fields. The Configuration Menu screen appears.
-
Select Modify Existing Screen/Add and Remove Fields.
-
In the Screen field, make sure the correct screen is selected.
-
In the Fields section, select Add to Screen beside the appropriate field name.
-
At the bottom of the screen, select Save Changes.
-
On the Configuration Menu screen, select Close to return to the screen in design mode.
Remove a field from the database
Take care when removing fields from the database because all data associated with the fields is removed and cannot be retrieved. As an alternative, you can ‘delete’ fields from screens without removing them from the database, so that you can reinstate them later if required.
-
Access the screen in Configuration Mode.
-
At the top of the screen, select Tables & Fields. The Configuration Menu screen appears.
-
Select Modify Existing Screen/Add and Remove Fields.
-
In the Screen field, make sure the correct screen is selected.
-
In the Fields section, select Drop Field beside the appropriate field name. If you cannot see this option, it means that the field is needed for the table and cannot be removed.
-
At the bottom of the screen, select Save Changes. A warning message appears to reminds you that you may lose all data associated with the field.
-
To continue, select OK.